Beer–Lambert law calculator
Convert between absorbance and concentration and find the corresponding transmittance. Your inputs stay on your device.
Set up your task
Starting local processing
Ready. Processing stays in this browser.
2 Your result
Your result updates in this browser. Check your input if the result looks unexpected.
How to use Beer–Lambert law calculator
Use the Beer–Lambert law to calculate an absorbance from a concentration, or estimate concentration from a measured absorbance. The result also converts absorbance to percentage transmittance.
- Enter Molar absorptivity (L/(mol·cm)), Path length (cm), Concentration (mol/L) or absorbance for the selected mode.
- Use the units shown beside the inputs and compare the first result with your own calculation.
- Check the substitution and read the assumptions below before applying the result to a different exercise.
Supported inputs and limits
Enter path length in centimetres and molar absorptivity in L/(mol·cm). This is the ideal linear, single-absorber model at one wavelength.
How it works
Absorbance A = εlc. With molar absorptivity ε in L/(mol·cm), path length l in cm and concentration c in mol/L, the units cancel. If A is the known value, calculate c = A/(εl). Percentage transmittance is 100 × 10 raised to the power −A, because absorbance is the negative base-ten logarithm of the transmitted fraction.
With ε = 1,000 L/(mol·cm), l = 1 cm and c = 0.0002 mol/L, multiply the three values to get A = 0.2. This corresponds to about 63.1% transmittance. Run the reverse mode with absorbance 0.2 and the same first two inputs to recover 0.0002 mol/L.
Use the absorptivity for the same wavelength and chemical form as the sample. Change centimetres or millimetres to the units stated in the form. In teaching labs, instrument response, a mismatched blank, scattered light and concentrated samples can all affect how closely the readings follow a line.
A calibration curve may have a non-zero fitted intercept. This calculator assumes a known absorptivity and the ideal zero-intercept form. If you are following a calibration exercise, use its fitted intercept and slope instead. The printed steps help you see which part of the calculation would change.
Example
The pre-filled example starts with “Absorbance: 0.2”.
- Calculate
- Absorbance from concentration
- Molar absorptivity (L/(mol·cm))
- 1000
- Path length (cm)
- 1
- Concentration (mol/L) or absorbance for the selected mode
- 0.0002
Absorbance: 0.2 Transmittance: 63.0957344 % A = εlc, with εl = 1,000 L/mol A = 1,000 × 0.0002 Transmittance (%) = 100 × 10⁻ᴬ
Questions about Beer–Lambert law calculator
Does absorbance have a unit?
It is dimensionless. Instruments sometimes label it AU for absorbance units. Use the number as displayed.
Can I calculate concentration from percent transmittance?
Convert percent to a fraction and take its negative base-ten logarithm first. Then use concentration mode.
What does zero absorbance imply?
It corresponds to 100% transmittance relative to the reference used for that absorbance.